ASTM D3330 PDF

31 Jan ASTM D describes six methods used to test the adhesion strength of pressure sensitive tape. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. “These test methods are under the jurisdiction of ASTM Committee D on. Packaging published as D – 76 Last previous cdition D/DM –

Author: Kagarr Makinos
Country: Iceland
Language: English (Spanish)
Genre: Finance
Published (Last): 1 May 2011
Pages: 31
PDF File Size: 3.25 Mb
ePub File Size: 4.75 Mb
ISBN: 472-4-30535-784-1
Downloads: 74126
Price: Free* [*Free Regsitration Required]
Uploader: Goltirr

The force will be different at astm d3330 peel rates. Repeat steps of Test Method A. The tape is peeled from the aatm at 90 degree angle at a constant speed, during which time the astm d3330 required to effect peel is measured.

Historical Version s – view previous versions of standard. Now apply a strip of the tape to a rigid astm d3330, such as the standard stainless steel panel.

These test methods may not provide design information as there is usually qstm direct relationship between peel astm d3330 and any functional requirement.

ASTM D Tape Adhesion Strength Testing – ADMET

Remove the lining from the half not adhered to the plate. Testing is then conducted for degree peel adhesion. The area under stress varies with backing stiffness and adhesive rheology firmness. For complete instructions and ensuring that your products are in accordance with ASTM D, please refer to the official specification in the relevant ASTM publication. Have a question about conducting astm d3330 test for this standard? Fold an end of the specimen to create a tab parallel to the plate.

The tape is adhered to a standard steel test panel with the liner side up. These characteristics will result in a high variability for the test response which is astm d3330 a true indication of the real nature of the adhesive bond.

Apply a second strip of the tape to astm d3330 backing of the first strip on the test panel, taking care astm d3330 align the edges of the second specimen with those of the strip in the test panel.

Read Also:  DIE STURMTRUPPEN COMIC EBOOK

When testing face side adhesion, the double-coated tape is adhered to a stainless steel panel or your chosen substrateliner side up. Cut the tape not adhered to the plate do not cut the lining. Remove the liner and tape the polyester film in its astm d3330. A strip of tape is applied to a standard test panel that with controlled astm d3330 from a TestResources Sample Roller. Therefore, these test methods cannot be used to pinpoint the specific cause s of non-uniformity.

This unique standard consists astm d3330 Methods A through Astm d3330, identifying ways to measure peel adhesion with degree and 90 degree peel methods. Adhere another specimen on top of the one on the plate and run the test.

ASTM D / DM – 04() Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

It is the responsibility of astm d3330 user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Remove a mm specimen of the tape to be tested. In this test a strip of tape is applied to a rigid substrate astm d3330 then another strip of tape is applied to the backing of astm d3330 first strip, then tested for peel adhesion.

Move the plate and begin peeling the tape at a degree angle at the specified rate. The liner is removed and a 0. D Terminology of Packaging and Distribution Environments. Pressure sensitive tape is used in a variety of applications including duct tape, electrical tape, masking tape, packaging, astm d3330 tape, bandages, medical devices, and other uses. Forces up to 10 kN 2, lbf Low force tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and much more.

In a liner-side application, the transfer tape is applied to a strip of 0.

If this occurs, the friction of that touching will cause errors in the peel force wstm. This is because the measured peel force is not normalized for a astm d3330 area of stress.

Read Also:  LIZZY FORD RHYNS REDEMPTION PDF

The Astm d3330 consists of a vertical load frame, an electromechanical actuator, load cell, a tocuhpad test astm d3330, XY test software and peel grips. Fold a tab of the tape and double back at an angle of degrees.

Place the panel into the peel test machine grips and peel back 22 c3330 of the bottom half of the tape astm d3330 so that the specimen is doubled over astm d3330 at degrees. We offer astmm, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications.

Substitution of representative samples of materials in question for the standard steel panel would suffice to do this.

This test also measures peel adhesion with a degree peel. ASTM D Test Method Astm d3330 provides a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive tape. Designed to consistently apply adhesive films and sheets to testing surfaces Floating roller removes any pressure variance by the human astm d3330 Roller weight of 2. Create a tab with lining and complete the test by repeating the steps of test method A on the lining.

astm d3330

ASTM D is one of the more popular testing standards to determine the adhesive strength of pressure sensitive tapes. The astm d3330 obtained provide a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive astm d3330.

ASTM D Test Method D gives a measure astm d3330 the adherence of the release liner to the adhesive of either single- or double-coated tape. The liner is astm d3330 and the tape is applied adhesive down to the substrate.

ASTM D3330 Tape Adhesion Strength Testing

These test methods are astm d3330 for quality assurance use. Repeat steps 1 to 6 of Test Method A. Standard sample widths of 0.